Message ID | 20230625042706.3998722-1-alejandro@enedino.org |
---|---|
State | Accepted, archived |
Commit | ce3a2f4cec28290c8e530989f17243f1ada4e3bd |
Headers | show |
Series | runqemu: Fix automated call to runqemu-ifup | expand |
Hi Alejandro Thank you. I will prepare another patch to bring the ifdown script to the same level. There is still the <native-sysroot-basedir> parameter. But maybe after learning from ifup part of the story, when the autobuilder confirmed that everything is consistent again. Regards, Adrian
Sounds good to me!, to be fair, I do believe we are moving in the right direction, perhaps we're just missing a couple of test cases to expand our testing spectrum. Cheers, Alejandro On Sun, 25 Jun 2023 at 02:46, <adrian.freihofer@gmail.com> wrote: > Hi Alejandro > > Thank you. > I will prepare another patch to bring the ifdown script to the same > level. There is still the <native-sysroot-basedir> parameter. But maybe > after learning from ifup part of the story, when the autobuilder > confirmed that everything is consistent again. > > Regards, > Adrian > >
diff --git a/scripts/runqemu b/scripts/runqemu index e1aa5a925c..62774a3b98 100755 --- a/scripts/runqemu +++ b/scripts/runqemu @@ -1186,7 +1186,7 @@ to your build configuration. gid = os.getgid() uid = os.getuid() logger.info("Setting up tap interface under sudo") - cmd = ('sudo', self.qemuifup, str(uid), str(gid)) + cmd = ('sudo', self.qemuifup, str(gid)) try: tap = subprocess.check_output(cmd).decode('utf-8').strip() except subprocess.CalledProcessError as e: diff --git a/scripts/runqemu-ifup b/scripts/runqemu-ifup index c65ceaf1c8..05c9325b6b 100755 --- a/scripts/runqemu-ifup +++ b/scripts/runqemu-ifup @@ -30,7 +30,7 @@ if [ $EUID -ne 0 ]; then fi if [ $# -eq 2 ]; then - echo "Warning: uid parameter is ignored. It is no longer needed." + echo "Warning: uid parameter is ignored. It is no longer needed." >&2 GROUP="$2" elif [ $# -eq 1 ]; then GROUP="$1"
When runqemu tries to call runqemu-ifup to create tap devices, it checks the output of runqemu-ifup to get the newly created tap device. The behavior of runqemu-ifup was recently modified along with its output, it no longer expects the uid parameter to be passed and it prints out a warning if it was, since this warning was now part of the output runqemu tries to parse it and convert it to an int() which proved impossible. Pass the correct arguments to the runqemu-ifup call and echo the warning to stderr instead to make sure its not being parsed and used by runqemu in any case. Signed-off-by: Alejandro Enedino Hernandez Samaniego <alejandro@enedino.org> --- scripts/runqemu | 2 +- scripts/runqemu-ifup | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-)